Navigation

Trine 4100-32D -Flexibile Strike, 3 Hour Rating 12-24 AC / DC, 32D Finish

PDFPrint
Description
Trine 4100-32D -Flexibile Strike, 3 Hour Rating 12-24 AC / DC, 32D Finish
SKU: - TR 4100-32D
  • The Trine 4100 Electric Strike has 1 - 3/8" Shallow backset and Three Hour Fire Rated. included are the 4 most used faceplates to make specifying and installing easy. Covers 90%+ of Cylindrical & Mortise Lock configurations (without deadbolt), plus faceplates can be kept & used to help accomodate for door sag.
    Application: Most installations with cylindrical locks and deadlatches
    Designed to work with: Schlage "L" Series and Yale 8700 Series without relocationg the mounting tabs
    PoE Friendly
  • Durability: 1,000,000 Life Cycles
    Action: Fail secure standard (unlocks with power).
    Grade: BHMA Grade 1 Electric Strike.
    Handing: Non Handed
  • Electric Characteristics:
    Voltage: 12-24VAC/DC
    Amps:
    12VDC - 0.240 AMPS
    24VDC - 0.114 AMPS
    12VAC - 0.210 AMPS
    16VAC - 0.280 AMPS
    24VAC -0 .420 AMPS
    Ohms:
    12VDC - 50.0
    24VDC - 210.0
    12VAC - 50.0
    16VAC - 50.0
    24VAC - 50.0
    Duty: AC - Intermittent (Buzzing)DC - Intermittent /Continuous (Silent)
    Lead Colors:
    16VAC - Red/blue
    24VAC - Red/blue
    12VDC - Red/blue
    24VDC - brown/Red
    12VAC - Red/blue
    Latch Length: For use with locksets having up to 5/8" throw
    Dimensions:
    Face Plate: 4-7/8" x 1-1/4"
    Mortise Backset: 1-3/8"
    Cavity Offset: Based on face plate -None - Centered, 19/32", 29/32" or 11/64"
    Cavity Depth: 3/4"
    Cavity Width: 25/32"
    Cavity Height: 1-3/8" to 3-1/4" based on Face plate
    Finish: Stainless Steel 32D
    Specifications:
    Class A, 3 Hour fire rated single door / frame configuration
    WH recognized for UL10C, Fire Tests of Door Assemblies
    UBC 7-2, Uniform building Code
    CAN4 S104, Standard Method for Fire Tests of Door Assemblies
    NFPA 252 - Issue: 1999/01/01 Standard Methods of Fire Tests of Door Assemblies
    NOTE: WH fire listing is void when using fail safe action.
    UL® Listed 1034: Burglary Resistant
    UL294 (6th Edition) listed
    ANSI/BHMA A156.5 - 1992 - 4-7/8" x 1-1/4" Fits