Electric Characteristics:
Voltage: 12-24VAC/DC
Amps:
12VDC - 0.240 AMPS
24VDC - 0.114 AMPS
12VAC - 0.210 AMPS
16VAC - 0.280 AMPS
24VAC -0 .420 AMPS
Ohms:
12VDC - 50.0
24VDC - 210.0
12VAC - 50.0
16VAC - 50.0
24VAC - 50.0
Duty: AC - Intermittent (Buzzing)DC - Intermittent /Continuous (Silent)
Lead Colors:
16VAC - Red/blue
24VAC - Red/blue
12VDC - Red/blue
24VDC - brown/Red
12VAC - Red/blue
Dimensions:
Face Plate: 4-7/8" x 1-1/4"
Mortise Backset: 1-3/8"
Cavity Offset: Based on face plate -None - Centered, 19/32", 29/32" or 11/64"
Cavity Depth: 3/4"
Cavity Width: 25/32"
Cavity Height: 1-3/8" to 3-1/4" based on Face plate
Specifications:
Class A, 3 Hour fire rated single door / frame configuration
WH recognized for UL10C, Fire Tests of Door Assemblies
UBC 7-2, Uniform building Code
CAN4 S104, Standard Method for Fire Tests of Door Assemblies
NFPA 252 - Issue: 1999/01/01 Standard Methods of Fire Tests of Door Assemblies
NOTE: WH fire listing is void when using fail safe action.
UL® Listed 1034: Burglary Resistant
UL294 (6th Edition) listed
ANSI/BHMA A156.5 - 1992 - 4-7/8" x 1-1/4" Fits